Summary

Average rating

D67

Westminster average: C 69

Homes in W1J have an average EPC rating of D (67), a little below the Westminster average of C (69). 90% of homes here are flats or maisonettes, and 62% have solid walls with no insulation.

W1J has the joint 3rd lowest average rating of the 25 postcode districts in Westminster. 36% of homes are heated by communal or district heating.

Rated D or worse
46%
Westminster: 38%
Typical yearly energy cost
£844
EPCs since 2021, at prices then
Built before 1930
58%

For landlords: 47% of privately rented homes here are below C (479 homes), the minimum from October 2030. See the 2030 rules

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the Westminster average.

  • Band A, score 92 to 100: 0% of homes; Westminster <1%.
  • Band B, score 81 to 91: 14% of homes; Westminster 14%.
  • Band C, score 69 to 80: 40% of homes; Westminster 48%.
  • Band D, score 55 to 68: 28% of homes; Westminster 29%.
  • Band E, score 39 to 54: 15% of homes; Westminster 8%.
  • Band F, score 21 to 38: 2% of homes; Westminster <1%.
  • Band G, score 1 to 20: 2% of homes; Westminster <1%.

Based on the latest energy performance certificate (EPC) for each of 1,340 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100.

Find the EPC for a home in W1J → Search any address on the official EPC register on GOV.UK. Certificates are free to view and last 10 years. Need a new EPC in W1J? → You need one to sell or let a home. GOV.UK explains how to find an accredited assessor.

Postcode sectors in W1J

Smaller areas within W1J, each with its own page. They're also on the map.

Sectors with fewer than 30 homes on the EPC register aren't shown.

What homes here are like

What EPC assessors recorded when they visited homes in W1J.

Main heating

Gas boiler39%
Communal or district heating36%
Other electric heating12%
Electric storage heaters6%
Heat pump4%
Oil boiler3%

Walls, roof and windows

Solid walls, not insulated62%
Cavity walls, not insulated5%
Cavity walls, insulated5%
Solid walls, insulated6%
Other walls (timber, system-built or modern)22%
Loft insulation under 100 mm (homes with a loft)61%
Double or triple glazing throughout55%

Ratings by type of home

Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.

Type of homeShare of homesAverage ratingRated D or worse
Terraced house9%D 62Westminster: D 6362%
Flat or maisonette90%D 67Westminster: C 7044%

Typical floor area is the median. Types with fewer than 20 homes here aren't shown.

Privately rented homes and the 2030 standard

Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.

47%

of privately rented homes here are below C (479 homes)

Westminster: 41%

  • 81% of those could reach C with the upgrades listed on their EPC.
  • 1% are rated F or G, below today's minimum of E (Westminster: <1%).

From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK

Upgrades recommended for homes in W1J

Upgrades that are unusually common here come first, then the ones that appear most often on local EPCs. Costs are the EPC's guide prices, not quotes.

  • Draught proofing More common here

    On 23% of EPCs here (England and Wales: 4%).

    Typical cost: £80–£120
  • Double glazing More common here

    On 40% of EPCs here (England and Wales: 9%). 45% of homes aren't fully double or triple glazed.

    Typical cost: £3,300–£6,500
  • Solid wall insulation (internal or external) More common here

    On 61% of EPCs here (England and Wales: 24%). 62% of homes here have solid walls with no insulation.

    Typical cost: £4,000–£14,000
  • New condensing boiler

    On 11% of EPCs here (England and Wales: 20%).

    Typical cost: £2,200–£3,000
  • Roof insulation (flat roof or room in roof)

    On 10% of EPCs here (England and Wales: 7%).

    Typical cost: £900–£1,500
  • Solar panels (PV)

    On 9% of EPCs here (England and Wales: 66%).

    Typical cost: £5,000–£8,000

With all its recommended upgrades, 85% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £190 a year, at the prices used when each EPC was issued.

Map of W1J and nearby areas

W1J's postcode sectors, and how it compares with the districts around it.

EC1N, Camden: C 71EC1R, Islington: D 68EC4A, City of London: C 69EC4Y, City of London: D 66NW1, Camden: C 70NW8, Westminster: C 69SE1, Southwark: C 74SE11, Lambeth: C 72SW1A, Westminster: C 69SW1E, Westminster: C 76SW1H, Westminster: C 78SW1P, Westminster: C 72SW1V, Westminster: C 69SW1W, Westminster: C 71SW1X, Kensington and Chelsea: D 65SW1Y, Westminster: D 66SW3, Kensington and Chelsea: D 66SW7, Kensington and Chelsea: D 66W1B, Westminster: C 73W1C: not enough EPCs to showW1D, Westminster: D 67W1F, Westminster: C 72W1G, Westminster: D 66W1H, Westminster: D 68W1K, Westminster: D 67W1S, Westminster: C 70W1T, Camden: C 72W1U, Westminster: C 69W1W, Westminster: C 71W2, Westminster: C 69WC1A, Camden: C 70WC1B, Camden: D 66WC1E, Camden: D 68WC1H, Camden: C 69WC1N, Camden: D 67WC1R, Camden: D 68WC1V, Camden: C 73WC2A, Westminster: C 79WC2B, Westminster: C 70WC2E, Westminster: C 70WC2H, Camden: C 70WC2N, Westminster: C 70WC2R, Westminster: C 80W1J 0: E 49W1J 5: D 67W1J 6: D 62W1J 7: D 66W1J 8: C 73W1J 0E 49W1J 5D 67W1J 7D 66W1J 8C 73SW1HC 78SW1YD 66W1CW1KD 67W1SC 70W1J 0E 49W1J 5D 67W1J 7D 66W1J 8C 73SW1HC 78SW1YD 66W1CW1DD 67W1KD 67W1SC 70
Colour shows each area's average rating. Tap an area to open it. A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 W1J boundary Not enough EPCs

Bordering postcode districts

Common questions

What holds energy ratings back in W1J?

About 62% of homes here have solid walls with no insulation, which lose much more heat than insulated walls. 58% were built before 1930. Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.

Are there grants for upgrades?

Some upgrades may qualify for government schemes, such as the Boiler Upgrade Scheme for heat pumps. Check current eligibility on GOV.UK.

How up to date is this?

We use the latest certificate for each home and refresh the data monthly. A certificate describes a home on the day it was assessed, so later improvements won't show until a new EPC is done.