Average rating

D66

Nottingham average: D 67

Homes in NG8 have an average EPC rating of D (66), about the same as the Nottingham average of D (67).

NG8 has the joint lowest average rating of the 7 postcode districts in Nottingham.

Rated D or worse
53%
Nottingham: 48%
Typical yearly energy cost
£980
EPCs since 2021, at prices then
Built before 1930
6%

For landlords: 63% of privately rented homes here are below C (2,924 homes), the minimum from October 2030. See the 2030 rules

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the Nottingham average.

  • Band A, score 92 to 100: <1% of homes; Nottingham <1%.
  • Band B, score 81 to 91: 10% of homes; Nottingham 10%.
  • Band C, score 69 to 80: 37% of homes; Nottingham 42%.
  • Band D, score 55 to 68: 40% of homes; Nottingham 35%.
  • Band E, score 39 to 54: 11% of homes; Nottingham 11%.
  • Band F, score 21 to 38: 2% of homes; Nottingham 1%.
  • Band G, score 1 to 20: <1% of homes; Nottingham <1%.

Based on the latest energy performance certificate (EPC) for each of 21,662 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100.

Find the EPC for a home in NG8 → Search any address on the official EPC register on GOV.UK. Certificates are free to view and last 10 years. Need a new EPC in NG8? → You need one to sell or let a home. GOV.UK explains how to find an accredited assessor.

Postcode sectors in NG8

Smaller areas within NG8, each with its own page. They're also on the map.

Sectors with fewer than 30 homes on the EPC register aren't shown.

What homes here are like

What EPC assessors recorded when they visited homes in NG8.

Main heating

Gas boiler95%
Electric storage heaters2%
Communal or district heating1%
Other electric heating1%

Walls, roof and windows

Solid walls, not insulated20%
Cavity walls, not insulated8%
Cavity walls, insulated47%
Solid walls, insulated6%
Other walls (timber, system-built or modern)20%
Loft insulation under 100 mm (homes with a loft)15%
Double or triple glazing throughout91%
Solar panels8%

Ratings by type of home

Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.

Type of homeShare of homesAverage ratingRated D or worse
Detached house16%D 61Nottingham: D 6170%
Semi-detached house32%D 66Nottingham: D 6457%
Terraced house29%D 68Nottingham: D 6649%
Bungalow13%D 68Nottingham: D 6852%
Flat or maisonette10%C 71Nottingham: C 7225%

Typical floor area is the median. Types with fewer than 20 homes here aren't shown.

Privately rented homes and the 2030 standard

Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.

63%

of privately rented homes here are below C (2,924 homes)

Nottingham: 52%

  • 98% of those could reach C with the upgrades listed on their EPC.
  • &lt;1% are rated F or G, below today's minimum of E (Nottingham: <1%).

From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK

Upgrades recommended for homes in NG8

Upgrades that are unusually common here come first, then the ones that appear most often on local EPCs. Costs are the EPC's guide prices, not quotes.

  • Floor insulation More common here

    On 75% of EPCs here (England and Wales: 49%).

    Typical cost: £4,000–£6,000
  • Solar panels (PV)

    On 79% of EPCs here (England and Wales: 66%).

    Typical cost: £5,000–£8,000
  • Solar water heating

    On 78% of EPCs here (England and Wales: 56%).

    Typical cost: £4,000–£6,000
  • Solid wall insulation (internal or external)

    On 22% of EPCs here (England and Wales: 24%). 20% of homes here have solid walls with no insulation.

    Typical cost: £4,000–£14,000
  • New condensing boiler

    On 19% of EPCs here (England and Wales: 20%).

    Typical cost: £2,200–£3,000
  • Heating controls

    On 18% of EPCs here (England and Wales: 16%).

    Typical cost: £350–£450

With all its recommended upgrades, 96% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £146 a year, at the prices used when each EPC was issued.

Map of NG8 and nearby areas

NG8's postcode sectors, and how it compares with the districts around it.

DE7, Ilkeston: D 66DE72, Derby: D 64DE75, Heanor: D 65NG1, Nottingham: C 73NG10, Nottingham: D 64NG11, Nottingham: D 68NG12, Nottingham: C 70NG14, Nottingham: D 68NG15, Nottingham: C 69NG16, Nottingham: D 66NG2, Nottingham: D 66NG3, Nottingham: D 67NG4, Nottingham: D 65NG5, Nottingham: D 66NG6, Nottingham: D 66NG7, Nottingham: D 66NG80: not enough EPCs to showNG9, Nottingham: D 65NG90: not enough EPCs to showNG8 1: D 62NG8 2: D 63NG8 3: D 68NG8 4: C 69NG8 5: D 65NG8 6: C 70NG8 1D 62NG8 2D 63NG8 3D 68NG8 4C 69NG8 6C 70NG7D 66NG8 1D 62NG8 2D 63NG8 3D 68NG8 4C 69NG8 5D 65NG8 6C 70NG1C 73NG7D 66
Colour shows each area's average rating. Tap an area to open it. A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 NG8 boundary Not enough EPCs

Bordering postcode districts

Common questions

What holds energy ratings back in NG8?

Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.

Are there grants for upgrades?

Some upgrades may qualify for government schemes, such as the Boiler Upgrade Scheme for heat pumps. Check current eligibility on GOV.UK.

How up to date is this?

We use the latest certificate for each home and refresh the data monthly. A certificate describes a home on the day it was assessed, so later improvements won't show until a new EPC is done.