EPC ratings in GL17, Drybrook
Postcode district in Forest of Dean
Summary
Average rating
D57
Forest of Dean average: D 64
Homes in GL17 have an average EPC rating of D (57), well below the Forest of Dean average of D (64). 31% of homes here have solid walls with no insulation.
GL17 has the lowest average rating of the 6 postcode districts in Forest of Dean. 45% of homes are heated by oil boilers. Terraced houses rate best here, at D (62) on average; detached houses rate lowest, at E (54).
- Rated D or worse
- 73%
- Forest of Dean: 56%
- Typical yearly energy cost
- £1,507
- EPCs since 2021, at prices then
- Built before 1930
- 33%
For landlords: 66% of privately rented homes here are below C (244 homes), the minimum from October 2030. See the 2030 rules
How ratings are spread
Share of homes in each band, with the score range for each. The dark line marks the Forest of Dean average.
- Band A, score 92 to 100: 1% of homes; Forest of Dean 2%.
- Band B, score 81 to 91: 8% of homes; Forest of Dean 17%.
- Band C, score 69 to 80: 19% of homes; Forest of Dean 26%.
- Band D, score 55 to 68: 33% of homes; Forest of Dean 31%.
- Band E, score 39 to 54: 26% of homes; Forest of Dean 17%.
- Band F, score 21 to 38: 10% of homes; Forest of Dean 6%.
- Band G, score 1 to 20: 3% of homes; Forest of Dean 2%.
Based on the latest energy performance certificate (EPC) for each of 3,467 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100.
Postcode sectors in GL17
Smaller areas within GL17, each with its own page. They're also on the map.
Sectors with fewer than 30 homes on the EPC register aren't shown.
What homes here are like
What EPC assessors recorded when they visited homes in GL17.
Main heating
Walls, roof and windows
Ratings by type of home
Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.
| Type of home | Share of homes | Average rating | Rated D or worse | Typical floor area |
|---|---|---|---|---|
| Detached house | 36% | E 54Forest of Dean: D 61 | 77% | 127 m² |
| Semi-detached house | 29% | D 58Forest of Dean: D 64 | 74% | 84 m² |
| Terraced house | 13% | D 62Forest of Dean: C 69 | 61% | 78 m² |
| Bungalow | 16% | D 56Forest of Dean: D 61 | 79% | 75 m² |
| Flat or maisonette | 5% | C 69Forest of Dean: C 70 | 36% | 54 m² |
| Park home | <1% | E 39Forest of Dean: E 44 | 100% | 64 m² |
Typical floor area is the median. Types with fewer than 20 homes here aren't shown.
Privately rented homes and the 2030 standard
Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.
66%
of privately rented homes here are below C (244 homes)
Forest of Dean: 57%
- 87% of those could reach C with the upgrades listed on their EPC.
- 4% are rated F or G, below today's minimum of E (Forest of Dean: 3%).
From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK
Upgrades recommended for homes in GL17
Upgrades that are unusually common here come first, then the ones that appear most often on local EPCs. Costs are the EPC's guide prices, not quotes.
- Hot water cylinder insulation More common here
On 15% of EPCs here (England and Wales: 8%).
Typical cost: £15–£30 - Roof insulation (flat roof or room in roof) More common here
On 11% of EPCs here (England and Wales: 7%).
Typical cost: £900–£1,500 - Loft insulation top-up More common here
On 18% of EPCs here (England and Wales: 12%). 18% of homes with a loft have less than 100 mm of insulation.
Typical cost: £100–£350 - Solar panels (PV)
On 86% of EPCs here (England and Wales: 66%).
Typical cost: £5,000–£8,000 - Solar water heating
On 81% of EPCs here (England and Wales: 56%).
Typical cost: £4,000–£6,000 - Floor insulation
On 68% of EPCs here (England and Wales: 49%).
Typical cost: £4,000–£6,000
With all its recommended upgrades, 86% of homes here could reach a C rating or better.
On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £295 a year, at the prices used when each EPC was issued.
Map of GL17 and nearby areas
GL17's postcode sectors, and how it compares with the districts around it.
Bordering postcode districts
Common questions
What holds energy ratings back in GL17?
About 31% of homes here have solid walls with no insulation, which lose much more heat than insulated walls. 33% were built before 1930. Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.
Can I see the rating for my own home?
Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.
Are there grants for upgrades?
Some upgrades may qualify for government schemes, such as the Boiler Upgrade Scheme for heat pumps. Check current eligibility on GOV.UK.
How up to date is this?
We use the latest certificate for each home and refresh the data monthly. A certificate describes a home on the day it was assessed, so later improvements won't show until a new EPC is done.