Skip to content
EPCMap

How energy efficient are homes in TR20 (Penzance, Cornwall)?

Summary

Average rating

D56

Cornwall average: D 62

Homes in TR20 have an average EPC rating of D (56), well below the Cornwall average of D (62). 32% of homes here have solid walls with no insulation.

Rated D or worse
72%
Cornwall: 58%
Typical yearly energy cost
£1,327
EPCs since 2021, at prices then
Built before 1930
33%

For landlords: 86% of privately rented homes here are below C (502 homes), the minimum from October 2030. See the 2030 rules

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the Cornwall average.

  • Band A, score 92 to 100: 5% of homes; Cornwall 2%.
  • Band B, score 81 to 91: 8% of homes; Cornwall 14%.
  • Band C, score 69 to 80: 16% of homes; Cornwall 27%.
  • Band D, score 55 to 68: 26% of homes; Cornwall 29%.
  • Band E, score 39 to 54: 27% of homes; Cornwall 18%.
  • Band F, score 21 to 38: 13% of homes; Cornwall 7%.
  • Band G, score 1 to 20: 6% of homes; Cornwall 3%.

Based on the latest energy performance certificate (EPC) for each of 3,712 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100.

Postcode sectors in TR20

Smaller areas within TR20, each with its own page. They're also on the map.

Sectors with fewer than 30 homes on the EPC register aren't shown.

What homes here are like

What EPC assessors recorded when they visited homes in TR20.

Main heating

Oil boiler40%
Gas boiler18%
Electric storage heaters17%
Heat pump11%
Other electric heating9%
Solid fuel or wood2%
Communal or district heating2%

Walls, roof and windows

Solid walls, not insulated32%
Cavity walls, not insulated13%
Cavity walls, insulated29%
Solid walls, insulated6%
Other walls (timber, system-built or modern)21%
Loft insulation under 100 mm (homes with a loft)21%
Double or triple glazing throughout84%
Solar panels3%

Ratings by type of home

Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.

Type of homeShare of homesAverage ratingRated D or worse
Detached house31%E 54Cornwall: D 6169%
Semi-detached house17%D 57Cornwall: D 6367%
Terraced house22%D 58Cornwall: D 6371%
Bungalow26%E 53Cornwall: D 5778%
Flat or maisonette5%D 58Cornwall: D 6872%

Typical floor area is the median. Types with fewer than 20 homes here aren't shown.

Privately rented homes and the 2030 standard

Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.

86%

of privately rented homes here are below C (502 homes)

Cornwall: 65%

  • 91% of those could reach C with the upgrades listed on their EPC.
  • 11% are rated F or G, below today's minimum of E (Cornwall: 5%).

From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK

Upgrades recommended for homes in TR20

Upgrades that are unusually common here come first, then the ones that appear most often on local EPCs. Costs are the EPC's guide prices, not quotes.

  • Insulated external doors More common here

    On 10% of EPCs here (England and Wales: 1%).

    Typical cost: £1,500
  • Modern storage heaters More common here

    On 20% of EPCs here (England and Wales: 6%). 26% of homes here are heated by electricity.

    Typical cost: £1,200–£1,800
  • Loft insulation top-up More common here

    On 20% of EPCs here (England and Wales: 12%). 21% of homes with a loft have less than 100 mm of insulation.

    Typical cost: £100–£350
  • Hot water cylinder insulation More common here

    On 14% of EPCs here (England and Wales: 8%).

    Typical cost: £15–£30
  • Roof insulation (flat roof or room in roof) More common here

    On 12% of EPCs here (England and Wales: 7%).

    Typical cost: £900–£1,500
  • Double glazing More common here

    On 15% of EPCs here (England and Wales: 9%). 16% of homes aren't fully double or triple glazed.

    Typical cost: £3,300–£6,500

With all its recommended upgrades, 85% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £315 a year, at the prices used when each EPC was issued.

Map of TR20 and nearby areas

TR20's postcode sectors, and how it compares with the districts around it.

TR10, Penryn: D 65TR11, Falmouth: D 64TR12, Helston: E 53TR13, Helston: D 61TR14, Camborne: D 65TR15, Redruth: D 67TR16, Redruth: D 58TR17, Marazion: E 54TR18, Penzance: D 62TR19, Penzance: E 50TR26, St. Ives: D 64TR27, Hayle: D 63TR3, Truro: D 61TR4, Truro: D 59TR5, St. Agnes: D 57TR20 8: D 56TR20 9: D 55TR20 8D 56TR20 9D 55TR17E 54TR18D 62TR19E 50TR26D 64TR27D 63TR20 8D 56TR20 9D 55TR17E 54TR18D 62TR19E 50TR26D 64TR27D 63
Colour shows each area's average rating. Tap an area to open it. A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 TR20 boundary Not enough EPCs

Bordering postcode districts

Common questions

What holds energy ratings back in TR20?

About 32% of homes here have solid walls with no insulation, which lose much more heat than insulated walls. 33% were built before 1930. Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.

Are there grants for upgrades?

Some upgrades may qualify for government schemes, such as the Boiler Upgrade Scheme for heat pumps. Check current eligibility on GOV.UK.

How up to date is this?

We use the latest certificate for each home and refresh the data monthly. A certificate describes a home on the day it was assessed, so later improvements won't show until a new EPC is done.